Informacja

Drogi użytkowniku, aplikacja do prawidłowego działania wymaga obsługi JavaScript. Proszę włącz obsługę JavaScript w Twojej przeglądarce.

Przeglądasz jako GOŚĆ

Wyszukujesz frazę ""Phantoms, Imaging"" wg kryterium: Temat


Tytuł :
Axially rigid steerable needle with compliant active tip control.
Autorzy :
de Vries M; Department of Biomechanical Engineering, Delft University of Technology, Delft, the Netherlands.
Sikorski J; Department of Biomechanical Engineering, University of Twente, Enschede, the Netherlands.; Department of Biomedical Engineering, University of Groningen and University Medical Center Groningen, Groningen, the Netherlands.
Misra S; Department of Biomechanical Engineering, University of Twente, Enschede, the Netherlands.; Department of Biomedical Engineering, University of Groningen and University Medical Center Groningen, Groningen, the Netherlands.
van den Dobbelsteen JJ; Department of Biomechanical Engineering, Delft University of Technology, Delft, the Netherlands.
Pokaż więcej
Źródło :
PloS one [PLoS One] 2021 Dec 16; Vol. 16 (12), pp. e0261089. Date of Electronic Publication: 2021 Dec 16 (Print Publication: 2021).
Typ publikacji :
Journal Article
MeSH Terms :
Phantoms, Imaging*
Brachytherapy/*instrumentation
Finite Element Analysis/*statistics & numerical data
Needles/*standards
Prostate/*surgery
Ultrasonography/*methods
Animals ; Brachytherapy/methods ; Cattle ; Equipment Design ; Humans ; Male ; Prostate/diagnostic imaging
Czasopismo naukowe
Tytuł :
Projection-based stereolithography for direct 3D printing of heterogeneous ultrasound phantoms.
Autorzy :
Paulsen SJ; Department of Bioengineering, Rice University, Houston, TX, United States of America.
Mitcham TM; Department of Imaging Physics, Division of Diagnostic Imaging, The University of Texas MD Anderson Cancer Center, Houston, TX, United States of America.; The University of Texas MD Anderson Cancer Center Graduate School of Biomedical Sciences, Houston, TX, United States of America.
Pan CS; Department of Bioengineering, Rice University, Houston, TX, United States of America.
Long J; Department of Imaging Physics, Division of Diagnostic Imaging, The University of Texas MD Anderson Cancer Center, Houston, TX, United States of America.
Grigoryan B; Department of Bioengineering, Rice University, Houston, TX, United States of America.
Sazer DW; Department of Bioengineering, Rice University, Houston, TX, United States of America.
Harlan CJ; Department of Imaging Physics, Division of Diagnostic Imaging, The University of Texas MD Anderson Cancer Center, Houston, TX, United States of America.; The University of Texas MD Anderson Cancer Center Graduate School of Biomedical Sciences, Houston, TX, United States of America.
Janson KD; Department of Bioengineering, Rice University, Houston, TX, United States of America.
Pagel MD; The University of Texas MD Anderson Cancer Center Graduate School of Biomedical Sciences, Houston, TX, United States of America.; Department of Cancer Systems Imaging, Division of Diagnostic Imaging, The University of Texas MD Anderson Cancer Center, Houston, TX, United States of America.
Miller JS; Department of Bioengineering, Rice University, Houston, TX, United States of America.
Bouchard RR; Department of Imaging Physics, Division of Diagnostic Imaging, The University of Texas MD Anderson Cancer Center, Houston, TX, United States of America.; The University of Texas MD Anderson Cancer Center Graduate School of Biomedical Sciences, Houston, TX, United States of America.
Pokaż więcej
Źródło :
PloS one [PLoS One] 2021 Dec 09; Vol. 16 (12), pp. e0260737. Date of Electronic Publication: 2021 Dec 09 (Print Publication: 2021).
Typ publikacji :
Journal Article; Research Support, N.I.H., Extramural; Research Support, Non-U.S. Gov't; Research Support, U.S. Gov't, Non-P.H.S.
MeSH Terms :
Phantoms, Imaging*
Printing, Three-Dimensional/*instrumentation
Stereolithography/*instrumentation
Ultrasonography/*methods
Hemodynamics ; Humans
Czasopismo naukowe
Tytuł :
Cardiac SPECT radiomic features repeatability and reproducibility: A multi-scanner phantom study.
Autorzy :
Edalat-Javid M; Department of Energy Engineering and Physics, Amir Kabir University of Technology, Tehran, Iran.
Shiri I; Division of Nuclear Medicine and Molecular Imaging, Geneva University Hospital, 1211, Geneva 4, Switzerland.
Hajianfar G; Rajaie Cardiovascular Medical and Research Center, Iran University of Medical Science, Tehran, Iran.
Abdollahi H; Department of Radiologic Sciences and Medical Physics, Faculty of Allied Medicine, Kerman University, Kerman, Iran.
Arabi H; Division of Nuclear Medicine and Molecular Imaging, Geneva University Hospital, 1211, Geneva 4, Switzerland.
Oveisi N; School of Population and Public Health, The University of British Columbia, Vancouver, BC, V6T 1Z4, Canada.
Javadian M; Department of Computer Engineering, Faculty of Information Technology, Kermanshah University of Technology, Kermanshah, Iran.
Shamsaei Zafarghandi M; Department of Energy Engineering and Physics, Amir Kabir University of Technology, Tehran, Iran.
Malek H; Rajaie Cardiovascular Medical and Research Center, Iran University of Medical Science, Tehran, Iran.
Bitarafan-Rajabi A; Rajaie Cardiovascular Medical and Research Center, Iran University of Medical Science, Tehran, Iran.; Cardiovascular Intervention Research Center, Rajaie Cardiovascular Medical and Research Center, Iran University of Medical Sciences, Tehran, Iran.; Echocardiography Research Center, Rajaie Cardiovascular Medical and Research Center, Iran University of Medical Sciences, Tehran, Iran.
Oveisi M; Rajaie Cardiovascular Medical and Research Center, Iran University of Medical Science, Tehran, Iran.; Department of Computer Science, University of British Columbia, Vancouver, BC, Canada.
Zaidi H; Division of Nuclear Medicine and Molecular Imaging, Geneva University Hospital, 1211, Geneva 4, Switzerland. .; Geneva University Neurocenter, Geneva University, 1205, Geneva, Switzerland. .; Department of Nuclear Medicine and Molecular Imaging, University of Groningen, University Medical Center Groningen, Groningen, The Netherlands. .; Department of Nuclear Medicine, University of Southern Denmark, Odense, Denmark. .
Pokaż więcej
Źródło :
Journal of nuclear cardiology : official publication of the American Society of Nuclear Cardiology [J Nucl Cardiol] 2021 Dec; Vol. 28 (6), pp. 2730-2744. Date of Electronic Publication: 2020 Apr 24.
Typ publikacji :
Journal Article
MeSH Terms :
Image Processing, Computer-Assisted*
Phantoms, Imaging*
Cardiac Imaging Techniques/*methods
Tomography, Emission-Computed, Single-Photon/*methods
Humans ; Reproducibility of Results ; Single Photon Emission Computed Tomography Computed Tomography
Czasopismo naukowe
Tytuł :
Experimental tissue mimicking human head phantom for estimation of stroke using IC-CF-DMAS algorithm in microwave based imaging system.
Autorzy :
Islam MS; Department of Electrical, Electronic and Systems Engineering, Faculty of Engineering and Built Environment, Universiti Kebangsaan Malaysia, 43600, Bangi, Selangor, Malaysia.
Islam MT; Department of Electrical, Electronic and Systems Engineering, Faculty of Engineering and Built Environment, Universiti Kebangsaan Malaysia, 43600, Bangi, Selangor, Malaysia. .
Almutairi AF; Electrical Engineering Department, College of Engineering and Petroleum, Kuwait University, 13060, Safat, Kuwait. .
Pokaż więcej
Źródło :
Scientific reports [Sci Rep] 2021 Nov 10; Vol. 11 (1), pp. 22015. Date of Electronic Publication: 2021 Nov 10.
Typ publikacji :
Journal Article; Research Support, Non-U.S. Gov't
MeSH Terms :
Microwaves*
Phantoms, Imaging*
Stroke/*diagnostic imaging
Algorithms ; Head/diagnostic imaging ; Humans
Czasopismo naukowe
Tytuł :
An Angle Independent Depth Aware Fusion Beamforming Approach for Ultrafast Ultrasound Flow Imaging .
Autorzy :
Madhavanunni AN
Raveendranatha Panicker M
Pokaż więcej
Źródło :
Annual International Conference of the IEEE Engineering in Medicine and Biology Society. IEEE Engineering in Medicine and Biology Society. Annual International Conference [Annu Int Conf IEEE Eng Med Biol Soc] 2021 Nov; Vol. 2021, pp. 3399-3402.
Typ publikacji :
Journal Article; Research Support, Non-U.S. Gov't
MeSH Terms :
Phantoms, Imaging*
Computer Simulation ; Ultrasonography
Czasopismo naukowe
Tytuł :
Slant-Stack Migration Applied to Plane-Wave Ultrasound Imaging.
Autorzy :
Rakhmatov D
Pokaż więcej
Źródło :
Annual International Conference of the IEEE Engineering in Medicine and Biology Society. IEEE Engineering in Medicine and Biology Society. Annual International Conference [Annu Int Conf IEEE Eng Med Biol Soc] 2021 Nov; Vol. 2021, pp. 4027-4030.
Typ publikacji :
Journal Article; Research Support, Non-U.S. Gov't
MeSH Terms :
Phantoms, Imaging*
Heart Rate ; Ultrasonography
Czasopismo naukowe
Tytuł :
ApodNet: Learning for High Frame Rate Synthetic Transmit Aperture Ultrasound Imaging.
Autorzy :
Chen Y
Liu J
Luo X
Luo J
Pokaż więcej
Źródło :
IEEE transactions on medical imaging [IEEE Trans Med Imaging] 2021 Nov; Vol. 40 (11), pp. 3190-3204. Date of Electronic Publication: 2021 Oct 27.
Typ publikacji :
Journal Article; Research Support, Non-U.S. Gov't
MeSH Terms :
Phantoms, Imaging*
Humans ; Signal-To-Noise Ratio ; Ultrasonography
Czasopismo naukowe
Tytuł :
MR relaxation properties of tissue-mimicking phantoms.
Autorzy :
Antoniou A; Department of Electrical Engineering, Computer Engineering, and Informatics, Cyprus University of Technology, Limassol, Cyprus.
Damianou C; Department of Electrical Engineering, Computer Engineering, and Informatics, Cyprus University of Technology, Limassol, Cyprus. Electronic address: .
Pokaż więcej
Źródło :
Ultrasonics [Ultrasonics] 2022 Feb; Vol. 119, pp. 106600. Date of Electronic Publication: 2021 Oct 04.
Typ publikacji :
Journal Article
MeSH Terms :
Phantoms, Imaging*
Agar/*chemistry
Biomimetic Materials/*chemistry
Magnetic Resonance Imaging/*methods
Equipment Design ; Temperature
Czasopismo naukowe
Tytuł :
Enhancement-constrained acceleration: A robust reconstruction framework in breast DCE-MRI.
Autorzy :
Easley TO; McKelvey School of Engineering, Washington University in St. Louis, St. Louis, Missouri, United States of America.
Ren Z; Department of Radiology, University of Chicago, Chicago, Illinois, United States of America.
Kim B; Department of Biostatistics at the University of Washington, Seattle, Washington, United States of America.
Karczmar GS; Department of Radiology, University of Chicago, Chicago, Illinois, United States of America.
Barber RF; Department of Statistics, University of Chicago, Chicago, Illinois, United States of America.
Pineda FD; Department of Radiology, University of Chicago, Chicago, Illinois, United States of America.
Pokaż więcej
Źródło :
PloS one [PLoS One] 2021 Oct 28; Vol. 16 (10), pp. e0258621. Date of Electronic Publication: 2021 Oct 28 (Print Publication: 2021).
Typ publikacji :
Journal Article; Research Support, N.I.H., Extramural; Research Support, U.S. Gov't, Non-P.H.S.
MeSH Terms :
Algorithms*
Contrast Media*
Phantoms, Imaging*
Breast/*pathology
Breast Neoplasms/*diagnosis
Image Enhancement/*methods
Magnetic Resonance Imaging/*methods
Computer Simulation ; Female ; Humans ; Image Interpretation, Computer-Assisted
Czasopismo naukowe
Tytuł :
Sub pixel resolution using spectral-spatial encoding in x-ray imaging.
Autorzy :
Szczykutowicz TP; Department of Radiology, University of Wisconsin-Madison, Madison, WI, United States of America.; Department of Medical Physics, University of Wisconsin-Madison, Madison, WI, United States of America.; Department of Biomedical Engineering, University of Wisconsin-Madison, Madison, WI, United States of America.
Rose SD; Department of Diagnostic and Interventional Imaging, UT Health Sciences Center at Houston, Houston, TX, United States of America.
Kitt A; EWI, Buffalo, NY, United States of America.
Pokaż więcej
Źródło :
PloS one [PLoS One] 2021 Oct 27; Vol. 16 (10), pp. e0258481. Date of Electronic Publication: 2021 Oct 27 (Print Publication: 2021).
Typ publikacji :
Journal Article
MeSH Terms :
Phantoms, Imaging*
Tomography, X-Ray Computed*
X-Rays
Czasopismo naukowe
Tytuł :
Dose reduction potential in cone-beam CT imaging of upper extremity joints with a twin robotic x-ray system.
Autorzy :
Luetkens KS; Department of Diagnostic and Interventional Radiology, University Hospital Würzburg, Oberdürrbacher Straße 6, 97080, Würzburg, Germany. .
Ergün S; Institute of Anatomy and Cell Biology, University of Würzburg, Koellikerstraße 6, 97070, Würzburg, Germany.
Huflage H; Department of Diagnostic and Interventional Radiology, University Hospital Würzburg, Oberdürrbacher Straße 6, 97080, Würzburg, Germany.
Kunz AS; Department of Diagnostic and Interventional Radiology, University Hospital Würzburg, Oberdürrbacher Straße 6, 97080, Würzburg, Germany.
Gietzen CH; Department of Diagnostic and Interventional Radiology, University Hospital Würzburg, Oberdürrbacher Straße 6, 97080, Würzburg, Germany.
Conrads N; Department of Diagnostic and Interventional Radiology, University Hospital Würzburg, Oberdürrbacher Straße 6, 97080, Würzburg, Germany.
Pennig L; Institute for Diagnostic and Interventional Radiology, Faculty of Medicine and University Hospital Cologne, University of Cologne, Kerpener Straße 62, 50937, Cologne, Germany.
Goertz L; Institute for Diagnostic and Interventional Radiology, Faculty of Medicine and University Hospital Cologne, University of Cologne, Kerpener Straße 62, 50937, Cologne, Germany.
Bley TA; Department of Diagnostic and Interventional Radiology, University Hospital Würzburg, Oberdürrbacher Straße 6, 97080, Würzburg, Germany.
Gassenmaier T; Department of Diagnostic and Interventional Radiology, University Hospital Würzburg, Oberdürrbacher Straße 6, 97080, Würzburg, Germany.
Grunz JP; Department of Diagnostic and Interventional Radiology, University Hospital Würzburg, Oberdürrbacher Straße 6, 97080, Würzburg, Germany.
Pokaż więcej
Źródło :
Scientific reports [Sci Rep] 2021 Oct 11; Vol. 11 (1), pp. 20176. Date of Electronic Publication: 2021 Oct 11.
Typ publikacji :
Journal Article; Research Support, Non-U.S. Gov't
MeSH Terms :
Phantoms, Imaging*
Cone-Beam Computed Tomography/*methods
Imaging, Three-Dimensional/*methods
Robotic Surgical Procedures/*methods
Upper Extremity/*diagnostic imaging
Cadaver ; Humans ; Radiation Dosage ; Upper Extremity/surgery ; X-Rays
Czasopismo naukowe
Tytuł :
Detectability of Lung Nodules in Ultra-low Dose CT.
Autorzy :
Janssen S; Department of Radiology and Nuclear Medicine, Medical Faculty Mannheim, University of Heidelberg, Mannheim, Germany.
Overhoff D; Department of Radiology and Nuclear Medicine, Medical Faculty Mannheim, University of Heidelberg, Mannheim, Germany.
Froelich MF; Department of Radiology and Nuclear Medicine, Medical Faculty Mannheim, University of Heidelberg, Mannheim, Germany.
Schoenberg SO; Department of Radiology and Nuclear Medicine, Medical Faculty Mannheim, University of Heidelberg, Mannheim, Germany.
Rathmann N; Department of Radiology and Nuclear Medicine, Medical Faculty Mannheim, University of Heidelberg, Mannheim, Germany .
Pokaż więcej
Źródło :
Anticancer research [Anticancer Res] 2021 Oct; Vol. 41 (10), pp. 5053-5058.
Typ publikacji :
Journal Article
MeSH Terms :
Phantoms, Imaging*
Early Detection of Cancer/*methods
Image Processing, Computer-Assisted/*methods
Lung Neoplasms/*diagnosis
Multiple Pulmonary Nodules/*diagnosis
Radiographic Image Interpretation, Computer-Assisted/*methods
Tomography, X-Ray Computed/*methods
Algorithms ; Follow-Up Studies ; Humans ; Lung Neoplasms/diagnostic imaging ; Multiple Pulmonary Nodules/diagnostic imaging ; Prognosis ; Prospective Studies ; Radiation Dosage
Czasopismo naukowe
Tytuł :
A Neonatal Phantom for Vital Signs Simulation.
Autorzy :
Lyra S
Voss F
Coenen A
Blase D
Aguirregomezcorta IB
Uguz DU
Leonhardt S
Antink CH
Pokaż więcej
Źródło :
IEEE transactions on biomedical circuits and systems [IEEE Trans Biomed Circuits Syst] 2021 Oct; Vol. 15 (5), pp. 949-959. Date of Electronic Publication: 2021 Dec 09.
Typ publikacji :
Journal Article; Research Support, Non-U.S. Gov't
MeSH Terms :
Infant, Premature*
Phantoms, Imaging*
Photoplethysmography*
Vital Signs*
Heart Rate ; Humans ; Infant, Newborn ; Oxygen Saturation
Czasopismo naukowe
Tytuł :
Soft Urinary Bladder Phantom for Endoscopic Training.
Autorzy :
Choi E; Cyber Valley Research Group, Institute of Physical Chemistry, University of Stuttgart, Pfaffenwaldring 55, 70569, Stuttgart, Germany.; Micro Nano and Molecular Systems Lab, Max Planck Institute for Intelligent Systems, Heisenbergstr. 3, 70569, Stuttgart, Germany.
Waldbillig F; Department of Urology & Urosurgery, University Medical Centre Mannheim, Faculty of Medicine, University of Heidelberg, Theodor-Kutzer-Ufer 1-3, 68167, Mannheim, Germany.; RaVeNNA 4pi - Consortium of the German Federal Ministry of Education and Research (BMBF), Mannheim, Germany.
Jeong M; Cyber Valley Research Group, Institute of Physical Chemistry, University of Stuttgart, Pfaffenwaldring 55, 70569, Stuttgart, Germany.; Micro Nano and Molecular Systems Lab, Max Planck Institute for Intelligent Systems, Heisenbergstr. 3, 70569, Stuttgart, Germany.
Li D; Cyber Valley Research Group, Institute of Physical Chemistry, University of Stuttgart, Pfaffenwaldring 55, 70569, Stuttgart, Germany.; Micro Nano and Molecular Systems Lab, Max Planck Institute for Intelligent Systems, Heisenbergstr. 3, 70569, Stuttgart, Germany.
Goyal R; Cyber Valley Research Group, Institute of Physical Chemistry, University of Stuttgart, Pfaffenwaldring 55, 70569, Stuttgart, Germany.; Micro Nano and Molecular Systems Lab, Max Planck Institute for Intelligent Systems, Heisenbergstr. 3, 70569, Stuttgart, Germany.
Weber P; Cyber Valley Research Group, Institute of Physical Chemistry, University of Stuttgart, Pfaffenwaldring 55, 70569, Stuttgart, Germany.
Miernik A; RaVeNNA 4pi - Consortium of the German Federal Ministry of Education and Research (BMBF), Mannheim, Germany.; Department of Urology, Faculty of Medicine, University of Freiburg - Medical Centre, Hugstetterstr. 55, 79106, Freiburg, Germany.
Grüne B; Department of Urology & Urosurgery, University Medical Centre Mannheim, Faculty of Medicine, University of Heidelberg, Theodor-Kutzer-Ufer 1-3, 68167, Mannheim, Germany.; RaVeNNA 4pi - Consortium of the German Federal Ministry of Education and Research (BMBF), Mannheim, Germany.
Hein S; RaVeNNA 4pi - Consortium of the German Federal Ministry of Education and Research (BMBF), Mannheim, Germany.; Department of Urology, Faculty of Medicine, University of Freiburg - Medical Centre, Hugstetterstr. 55, 79106, Freiburg, Germany.
Suarez-Ibarrola R; RaVeNNA 4pi - Consortium of the German Federal Ministry of Education and Research (BMBF), Mannheim, Germany.; Department of Urology, Faculty of Medicine, University of Freiburg - Medical Centre, Hugstetterstr. 55, 79106, Freiburg, Germany.
Kriegmair MC; Department of Urology & Urosurgery, University Medical Centre Mannheim, Faculty of Medicine, University of Heidelberg, Theodor-Kutzer-Ufer 1-3, 68167, Mannheim, Germany.; RaVeNNA 4pi - Consortium of the German Federal Ministry of Education and Research (BMBF), Mannheim, Germany.
Qiu T; Cyber Valley Research Group, Institute of Physical Chemistry, University of Stuttgart, Pfaffenwaldring 55, 70569, Stuttgart, Germany. .; Micro Nano and Molecular Systems Lab, Max Planck Institute for Intelligent Systems, Heisenbergstr. 3, 70569, Stuttgart, Germany. .
Pokaż więcej
Źródło :
Annals of biomedical engineering [Ann Biomed Eng] 2021 Sep; Vol. 49 (9), pp. 2412-2420. Date of Electronic Publication: 2021 May 17.
Typ publikacji :
Journal Article; Multicenter Study
MeSH Terms :
Phantoms, Imaging*
Urinary Bladder/*diagnostic imaging
Adult ; Aged ; Cystoscopy ; Humans ; Middle Aged ; Printing, Three-Dimensional ; Tomography, X-Ray Computed ; Urinary Bladder Neoplasms/diagnostic imaging
Czasopismo naukowe
Tytuł :
Soft Liver Phantom with a Hollow Biliary System.
Autorzy :
Tan X; Cyber Valley Research Group, Institute of Physical Chemistry, University of Stuttgart, Pfaffenwaldring 55, 70569, Stuttgart, Germany.; Department of General, Visceral and Transplant Surgery, University Hospital Tuebingen, 72072, Tuebingen, Germany.; Department of General Surgery, Xiangya Hospital Central South University, Changsha, 410008, China.
Li D; Cyber Valley Research Group, Institute of Physical Chemistry, University of Stuttgart, Pfaffenwaldring 55, 70569, Stuttgart, Germany.; Micro Nano and Molecular Systems Lab, Max Planck Institute for Intelligent Systems, Heisenbergstr. 3, 70569, Stuttgart, Germany.
Jeong M; Cyber Valley Research Group, Institute of Physical Chemistry, University of Stuttgart, Pfaffenwaldring 55, 70569, Stuttgart, Germany.
Yu T; Cyber Valley Research Group, Institute of Physical Chemistry, University of Stuttgart, Pfaffenwaldring 55, 70569, Stuttgart, Germany.; Micro Nano and Molecular Systems Lab, Max Planck Institute for Intelligent Systems, Heisenbergstr. 3, 70569, Stuttgart, Germany.
Ma Z; Micro Nano and Molecular Systems Lab, Max Planck Institute for Intelligent Systems, Heisenbergstr. 3, 70569, Stuttgart, Germany.
Afat S; Department of Interventional and Diagnostic Radiology, University Hospital Tuebingen, 72072, Tuebingen, Germany.
Grund KE; Department of General, Visceral and Transplant Surgery, University Hospital Tuebingen, 72072, Tuebingen, Germany.
Qiu T; Cyber Valley Research Group, Institute of Physical Chemistry, University of Stuttgart, Pfaffenwaldring 55, 70569, Stuttgart, Germany. .; Micro Nano and Molecular Systems Lab, Max Planck Institute for Intelligent Systems, Heisenbergstr. 3, 70569, Stuttgart, Germany. .
Pokaż więcej
Źródło :
Annals of biomedical engineering [Ann Biomed Eng] 2021 Sep; Vol. 49 (9), pp. 2139-2149. Date of Electronic Publication: 2021 Feb 16.
Typ publikacji :
Journal Article
MeSH Terms :
Phantoms, Imaging*
Biliary Tract/*diagnostic imaging
Liver/*diagnostic imaging
Endoscopy ; Models, Anatomic ; Tomography, X-Ray Computed ; Ultrasonography
Czasopismo naukowe
Tytuł :
Technical note: On the impact of the kV imaging configuration on doses from planar images during motion-synchronized treatments on Radixact®.
Autorzy :
Ferris WS; Department of Medical Physics, School of Medicine and Public Health, University of Wisconsin-Madison, Madison, Wisconsin, USA.
DeWerd LA; Department of Medical Physics, School of Medicine and Public Health, University of Wisconsin-Madison, Madison, Wisconsin, USA.
Bayouth JE; Department of Human Oncology, School of Medicine and Public Health, University of Wisconsin-Madison, Madison, Wisconsin, USA.
Culberson WS; Department of Medical Physics, School of Medicine and Public Health, University of Wisconsin-Madison, Madison, Wisconsin, USA.
Pokaż więcej
Źródło :
Journal of applied clinical medical physics [J Appl Clin Med Phys] 2021 Sep; Vol. 22 (9), pp. 227-231. Date of Electronic Publication: 2021 Jul 26.
Typ publikacji :
Journal Article
MeSH Terms :
Phantoms, Imaging*
Fluoroscopy ; Humans ; Motion ; Radiation Dosage ; Radiography
Czasopismo naukowe
Tytuł :
Stretchable self-tuning MRI receive coils based on liquid metal technology (LiquiTune).
Autorzy :
Motovilova E; Department of Radiology, Weill Cornell Medicine, New York, NY, 10065, USA. .; Department of Radiology, Hospital for Special Surgery, New York, NY, 10021, USA. .
Tan ET; Department of Radiology, Hospital for Special Surgery, New York, NY, 10021, USA.
Taracila V; GE Healthcare, Aurora, OH, USA.
Vincent JM; GE Healthcare, Aurora, OH, USA.
Grafendorfer T; GE Healthcare, Aurora, OH, USA.
Shin J; Department of Radiology, Weill Cornell Medicine, New York, NY, 10065, USA.
Potter HG; Department of Radiology, Hospital for Special Surgery, New York, NY, 10021, USA.
Robb FJL; GE Healthcare, Aurora, OH, USA.
Sneag DB; Department of Radiology, Hospital for Special Surgery, New York, NY, 10021, USA.
Winkler SA; Department of Radiology, Weill Cornell Medicine, New York, NY, 10065, USA. .
Pokaż więcej
Źródło :
Scientific reports [Sci Rep] 2021 Aug 10; Vol. 11 (1), pp. 16228. Date of Electronic Publication: 2021 Aug 10.
Typ publikacji :
Journal Article; Research Support, N.I.H., Extramural
MeSH Terms :
Phantoms, Imaging*
Signal-To-Noise Ratio*
Knee/*diagnostic imaging
Magnetic Resonance Imaging/*instrumentation
Magnetic Resonance Imaging/*methods
Humans
Czasopismo naukowe
Tytuł :
Applications of various range shifters for proton pencil beam scanning radiotherapy.
Autorzy :
Lin H; New York Proton Center, New York, 10035, USA. .
Shi C; New York Proton Center, New York, 10035, USA.
Huang S; New York Proton Center, New York, 10035, USA.
Shen J; Mayo Clinic, Phoenix, AZ, 85054, USA.
Kang M; New York Proton Center, New York, 10035, USA.
Chen Q; New York Proton Center, New York, 10035, USA.
Zhai H; New York Proton Center, New York, 10035, USA.
McDonough J; Department of Radiation Oncology, University of Pennsylvania, Philadelphia, PA, 19104, USA.
Tochner Z; Department of Radiation Oncology, University of Pennsylvania, Philadelphia, PA, 19104, USA.
Deville C; Department of Radiation Oncology and Molecular Radiation Sciences, Johns Hopkins University, Baltimore, MD, 21231, USA.
Simone CB 2nd; New York Proton Center, New York, 10035, USA.
Both S; Department of Radiation Oncology, University Medical Center Groningen, Groningen, 9713 GZ, Netherlands.
Pokaż więcej
Źródło :
Radiation oncology (London, England) [Radiat Oncol] 2021 Aug 06; Vol. 16 (1), pp. 146. Date of Electronic Publication: 2021 Aug 06.
Typ publikacji :
Journal Article
MeSH Terms :
Phantoms, Imaging*
Head and Neck Neoplasms/*radiotherapy
Organs at Risk/*radiation effects
Proton Therapy/*methods
Radiotherapy Planning, Computer-Assisted/*methods
Radiotherapy, Image-Guided/*methods
Algorithms ; Follow-Up Studies ; Head and Neck Neoplasms/diagnostic imaging ; Head and Neck Neoplasms/pathology ; Humans ; Image Processing, Computer-Assisted/methods ; Prognosis ; Radiotherapy Dosage ; Tomography, X-Ray Computed/methods
Czasopismo naukowe
Tytuł :
Generation of annotated multimodal ground truth datasets for abdominal medical image registration.
Autorzy :
Bauer DF; Computer Assisted Clinical Medicine, Mannheim Institute for Intelligent Systems in Medicine, Medical Faculty Mannheim, Heidelberg University, Mannheim, Germany. .
Russ T; Computer Assisted Clinical Medicine, Mannheim Institute for Intelligent Systems in Medicine, Medical Faculty Mannheim, Heidelberg University, Mannheim, Germany.
Waldkirch BI; Computer Assisted Clinical Medicine, Mannheim Institute for Intelligent Systems in Medicine, Medical Faculty Mannheim, Heidelberg University, Mannheim, Germany.
Tönnes C; Computer Assisted Clinical Medicine, Mannheim Institute for Intelligent Systems in Medicine, Medical Faculty Mannheim, Heidelberg University, Mannheim, Germany.
Segars WP; Carl E. Ravin Advanced Imaging Labs, Department of Radiology, Duke University, Durham, USA.
Schad LR; Computer Assisted Clinical Medicine, Mannheim Institute for Intelligent Systems in Medicine, Medical Faculty Mannheim, Heidelberg University, Mannheim, Germany.
Zöllner FG; Computer Assisted Clinical Medicine, Mannheim Institute for Intelligent Systems in Medicine, Medical Faculty Mannheim, Heidelberg University, Mannheim, Germany.
Golla AK; Computer Assisted Clinical Medicine, Mannheim Institute for Intelligent Systems in Medicine, Medical Faculty Mannheim, Heidelberg University, Mannheim, Germany.
Pokaż więcej
Źródło :
International journal of computer assisted radiology and surgery [Int J Comput Assist Radiol Surg] 2021 Aug; Vol. 16 (8), pp. 1277-1285. Date of Electronic Publication: 2021 May 02.
Typ publikacji :
Journal Article
MeSH Terms :
Algorithms*
Computer Simulation*
Phantoms, Imaging*
Cone-Beam Computed Tomography/*methods
Image Processing, Computer-Assisted/*methods
Magnetic Resonance Imaging/*methods
Humans
Czasopismo naukowe
Tytuł :
Verification of Surface Dose for Flattening Filter and Flattening Filter Free Beams in Beam-Matched Medical Linear Accelerators.
Autorzy :
Sushma N; Department of Radiation Physics, Kidwai Memorial Institute of Oncology, Bengaluru, India.; Division of Medical Physics, JSS Academy of Higher Education and Research, Mysuru, India.
Kaginelli S; Division of Medical Physics, JSS Academy of Higher Education and Research, Mysuru, India.
Palanivel S; Department of Radiation Physics, Kidwai Memorial Institute of Oncology, Bengaluru, India.
Ganesh KM; Department of Radiation Physics, Kidwai Memorial Institute of Oncology, Bengaluru, India.
Pokaż więcej
Źródło :
Asian Pacific journal of cancer prevention : APJCP [Asian Pac J Cancer Prev] 2021 Aug 01; Vol. 22 (8), pp. 2577-2585. Date of Electronic Publication: 2021 Aug 01.
Typ publikacji :
Journal Article
MeSH Terms :
Phantoms, Imaging*
Filtration/*instrumentation
Particle Accelerators/*instrumentation
Radiotherapy Planning, Computer-Assisted/*methods
Radiotherapy, Intensity-Modulated/*methods
Humans ; Radiotherapy Dosage
Czasopismo naukowe

Ta witryna wykorzystuje pliki cookies do przechowywania informacji na Twoim komputerze. Pliki cookies stosujemy w celu świadczenia usług na najwyższym poziomie, w tym w sposób dostosowany do indywidualnych potrzeb. Korzystanie z witryny bez zmiany ustawień dotyczących cookies oznacza, że będą one zamieszczane w Twoim komputerze. W każdym momencie możesz dokonać zmiany ustawień dotyczących cookies