Informacja

Drogi użytkowniku, aplikacja do prawidłowego działania wymaga obsługi JavaScript. Proszę włącz obsługę JavaScript w Twojej przeglądarce.

Wyszukujesz frazę ""Photoplethysmography"" wg kryterium: Temat


Tytuł:
Fundamental and Practical Feasibility of Electrocardiogram Reconstruction from Photoplethysmogram.
Autorzy:
Slapničar G; Department of Intelligent Systems, Jožef Stefan Institute, Jamova cesta 39, 1000 Ljubljana, Slovenia.; Jožef Stefan International Postgraduate School, Jamova cesta 39, 1000 Ljubljana, Slovenia.
Su J; Department of Electrical Engineering, Eindhoven University of Technology, 5612 AZ Eindhoven, The Netherlands.
Wang W; Department of Electrical Engineering, Eindhoven University of Technology, 5612 AZ Eindhoven, The Netherlands.; Biomedical Engineering Department, Southern University of Science and Technology, Shenzhen 518055, China.
Pokaż więcej
Źródło:
Sensors (Basel, Switzerland) [Sensors (Basel)] 2024 Mar 25; Vol. 24 (7). Date of Electronic Publication: 2024 Mar 25.
Typ publikacji:
Journal Article
MeSH Terms:
Photoplethysmography*
Electrocardiography*
Feasibility Studies ; Benchmarking ; Electricity
Czasopismo naukowe
Tytuł:
Exploring the Possibility of Photoplethysmography-Based Human Activity Recognition Using Convolutional Neural Networks.
Autorzy:
Ryu S; Department of Artificial Intelligence Convergence, Hallym University, Chuncheon 24252, Republic of Korea.; Cerebrovascular Disease Research Center, Hallym University, Chuncheon 24252, Republic of Korea.
Yun S; Department of Artificial Intelligence Convergence, Hallym University, Chuncheon 24252, Republic of Korea.; Cerebrovascular Disease Research Center, Hallym University, Chuncheon 24252, Republic of Korea.
Lee S; Cerebrovascular Disease Research Center, Hallym University, Chuncheon 24252, Republic of Korea.
Jeong IC; Department of Artificial Intelligence Convergence, Hallym University, Chuncheon 24252, Republic of Korea.; Cerebrovascular Disease Research Center, Hallym University, Chuncheon 24252, Republic of Korea.; Department of Population Health Science and Policy, Icahn School of Medicine at Mount Sinai, New York, NY 10029, USA.
Pokaż więcej
Źródło:
Sensors (Basel, Switzerland) [Sensors (Basel)] 2024 Mar 01; Vol. 24 (5). Date of Electronic Publication: 2024 Mar 01.
Typ publikacji:
Journal Article
MeSH Terms:
Photoplethysmography*/methods
Neural Networks, Computer*
Humans ; Prospective Studies ; Electrocardiography/methods ; Human Activities
Czasopismo naukowe
Tytuł:
Feasibility and accuracy of noninvasive continuous hemoglobin monitoring using transesophageal photoplethysmography in porcine model.
Autorzy:
Peng L; Department of Anesthesiology, West China Hospital, Sichuan University, 37 Guo Xue Xiang, Chengdu, 610041, China.
Zhao L; Department of Cardiovascular Surgery, The Third People's Hospital of Chengdu, 82 Qing Long Xiang, Chengdu, 610041, China.
Zhang X; Department of Anesthesiology, West China Hospital, Sichuan University, 37 Guo Xue Xiang, Chengdu, 610041, China.
Zhang Y; Department of Anesthesiology, West China Hospital, Sichuan University, 37 Guo Xue Xiang, Chengdu, 610041, China.
Ding M; Department of Anesthesiology, West China Hospital, Sichuan University, 37 Guo Xue Xiang, Chengdu, 610041, China.
Lin Z; Department of Physics, Sichuan University, Chengdu, 610064, China.
Jiang H; Department of Physics, Sichuan University, Chengdu, 610064, China.
Huang Y; Department of Physics, Sichuan University, Chengdu, 610064, China.
Gao B; Department of Physics, Sichuan University, Chengdu, 610064, China.
Wei W; Department of Anesthesiology, West China Hospital, Sichuan University, 37 Guo Xue Xiang, Chengdu, 610041, China. .
Pokaż więcej
Źródło:
BMC anesthesiology [BMC Anesthesiol] 2024 Feb 06; Vol. 24 (1), pp. 53. Date of Electronic Publication: 2024 Feb 06.
Typ publikacji:
Journal Article
MeSH Terms:
Photoplethysmography*
Oximetry*/methods
Swine ; Animals ; Feasibility Studies ; Blood Gas Analysis ; Hemoglobins/analysis
Czasopismo naukowe
Tytuł:
Introducing the Pi-CON Methodology to Overcome Usability Deficits during Remote Patient Monitoring.
Autorzy:
Baumann S; Industrial and Manufacturing Systems Engineering, Iowa State University, 2529 Union Dr, Ames, IA 50011, USA.
Stone R; Industrial and Manufacturing Systems Engineering, Iowa State University, 2529 Union Dr, Ames, IA 50011, USA.
Kim JY; Industrial and Manufacturing Systems Engineering, Iowa State University, 2529 Union Dr, Ames, IA 50011, USA.
Pokaż więcej
Źródło:
Sensors (Basel, Switzerland) [Sensors (Basel)] 2024 Apr 02; Vol. 24 (7). Date of Electronic Publication: 2024 Apr 02.
Typ publikacji:
Journal Article; Review
MeSH Terms:
Gait*
Photoplethysmography*
Humans ; Data Collection ; Monitoring, Physiologic ; Radar
Czasopismo naukowe
Tytuł:
On the use of fractional calculus to improve the pulse arrival time (PAT) detection when using photoplethysmography (PPG) and electrocardiography (ECG) signals.
Autorzy:
Mohammadpoor Faskhodi M; Department of Electronic Engineering, Universitat Politècnica de Catalunya, Barcelona, Spain.
A Garcia-Gonzalez M; Department of Electronic Engineering, Universitat Politècnica de Catalunya, Barcelona, Spain.
Fernandez-Chimeno M; Department of Electronic Engineering, Universitat Politècnica de Catalunya, Barcelona, Spain.
Guede-Fernández F; Department of Electronic Engineering, Universitat Politècnica de Catalunya, Barcelona, Spain.; Value for Health CoLAB, Lisbon, Portugal.
Mateu-Mateus M; Department of Electronic Engineering, Universitat Politècnica de Catalunya, Barcelona, Spain.
Capdevila L; Laboratory of Sport Psychology, Department of Basic Psychology, Universitat Autònoma de Barcelona (UAB), Bellaterra, Spain.; Sport Research Institute, Universitat Autònoma de Barcelona (UAB), Bellaterra, Spain.
J Ramos-Castro J; Department of Electronic Engineering, Universitat Politècnica de Catalunya, Barcelona, Spain.
Pokaż więcej
Źródło:
PloS one [PLoS One] 2024 Feb 16; Vol. 19 (2), pp. e0298354. Date of Electronic Publication: 2024 Feb 16 (Print Publication: 2024).
Typ publikacji:
Journal Article
MeSH Terms:
Photoplethysmography*/methods
Pulse Wave Analysis*/methods
Humans ; Heart Rate ; Time Factors ; Electrocardiography
Czasopismo naukowe
Tytuł:
Cardiac arrhythmias classification using photoplethysmography database.
Autorzy:
Qananwah Q; Department of Biomedical Systems and Informatics Engineering, Hijjawi Faculty for Engineering Technology, Yarmouk University, P.O.Box 21163, Irbid, Jordan. .
Ababneh M; Department of Computer Engineering, Hijjawi Faculty for Engineering Technology, Yarmouk University, Irbid, Jordan.
Dagamseh A; Department of Electronics Engineering, Hijjawi Faculty for Engineering Technology, Yarmouk University, Irbid, Jordan.
Pokaż więcej
Źródło:
Scientific reports [Sci Rep] 2024 Feb 09; Vol. 14 (1), pp. 3355. Date of Electronic Publication: 2024 Feb 09.
Typ publikacji:
Journal Article
MeSH Terms:
Photoplethysmography*
Tachycardia, Ventricular*/diagnosis
Humans ; Bradycardia ; Arrhythmias, Cardiac/diagnosis ; Signal Processing, Computer-Assisted ; Electrocardiography ; Algorithms
Czasopismo naukowe
Tytuł:
An Optical Signal Simulator for the Characterization of Photoplethysmographic Devices.
Autorzy:
Pittella E; Department of Information Engineering, Electronics and Telecommunications (DIET), Sapienza University of Rome, 00184 Rome, Italy.
Testa O; Department of Information Engineering, Electronics and Telecommunications (DIET), Sapienza University of Rome, 00184 Rome, Italy.
Podestà L; Department of Astronautical, Electrical and Energy Engineering (DIAEE), Sapienza University of Rome, 00184 Rome, Italy.
Piuzzi E; Department of Information Engineering, Electronics and Telecommunications (DIET), Sapienza University of Rome, 00184 Rome, Italy.
Pokaż więcej
Źródło:
Sensors (Basel, Switzerland) [Sensors (Basel)] 2024 Feb 04; Vol. 24 (3). Date of Electronic Publication: 2024 Feb 04.
Typ publikacji:
Journal Article
MeSH Terms:
Photoplethysmography*
Algorithms*
Heart Rate/physiology ; Artifacts ; Databases, Factual ; Signal Processing, Computer-Assisted
Czasopismo naukowe
Tytuł:
Red Blood Cells' Area Deformation as the Origin of the Photoplethysmography Signal.
Autorzy:
Evdochim L; Department of Electronic Devices, Circuits, and Architectures, Faculty of Electronics, Telecommunications and Information Technology, University Politehnica of Bucharest, 060042 Bucharest, Romania.
Chiriac E; National Institute for Research and Development in Microtechnologies-IMT Bucharest, 077190 Voluntari, Romania.
Avram M; National Institute for Research and Development in Microtechnologies-IMT Bucharest, 077190 Voluntari, Romania.
Dobrescu L; Department of Electronic Devices, Circuits, and Architectures, Faculty of Electronics, Telecommunications and Information Technology, University Politehnica of Bucharest, 060042 Bucharest, Romania.
Dobrescu D; Department of Electronic Devices, Circuits, and Architectures, Faculty of Electronics, Telecommunications and Information Technology, University Politehnica of Bucharest, 060042 Bucharest, Romania.
Stanciu S; Laboratory of Cardiovascular Noninvasive Investigations, Dr. Carol Davila Central Military Emergency University Hospital, 010242 Bucharest, Romania.
Halichidis S; Department of Clinical Medical Disciplines, Faculty of Medicine, Ovidius University of Constanta, 900527 Constanta, Romania.
Pokaż więcej
Źródło:
Sensors (Basel, Switzerland) [Sensors (Basel)] 2023 Nov 30; Vol. 23 (23). Date of Electronic Publication: 2023 Nov 30.
Typ publikacji:
Journal Article
MeSH Terms:
Photoplethysmography*
Erythrocytes*/physiology
Blood Flow Velocity ; Capillaries ; Microcirculation
Czasopismo naukowe
Tytuł:
Improved U-Net Model to Estimate Cardiac Output Based on Photoplethysmography and Arterial Pressure Waveform.
Autorzy:
Xu X; School of Electronic Engineering and Automation, Guilin University of Electronic Technology, Guilin 541004, China.
Tang Q; School of Life & Environmental Science, Guilin University of Electronic Technology, Guilin 541004, China.
Chen Z; School of Life & Environmental Science, Guilin University of Electronic Technology, Guilin 541004, China.
Pokaż więcej
Źródło:
Sensors (Basel, Switzerland) [Sensors (Basel)] 2023 Nov 09; Vol. 23 (22). Date of Electronic Publication: 2023 Nov 09.
Typ publikacji:
Journal Article
MeSH Terms:
Arterial Pressure*
Photoplethysmography*
Humans ; Cardiac Output ; Arteries ; Heart ; Blood Pressure
Czasopismo naukowe
Tytuł:
Remote Photoplethysmography and Motion Tracking Convolutional Neural Network with Bidirectional Long Short-Term Memory: Non-Invasive Fatigue Detection Method Based on Multi-Modal Fusion.
Autorzy:
Kong L; School of Electronic Information and Electrical Engineering, Yangtze University, Jingzhou 434023, China.
Xie K; School of Electronic Information and Electrical Engineering, Yangtze University, Jingzhou 434023, China.
Niu K; School of Electronic Information and Electrical Engineering, Yangtze University, Jingzhou 434023, China.
He J; School of Computer Science, Central South University, Changsha 410083, China.
Zhang W; School of Electronic Information, Central South University, Changsha 410083, China.
Pokaż więcej
Źródło:
Sensors (Basel, Switzerland) [Sensors (Basel)] 2024 Jan 11; Vol. 24 (2). Date of Electronic Publication: 2024 Jan 11.
Typ publikacji:
Journal Article
MeSH Terms:
Memory, Short-Term*
Photoplethysmography*
Neural Networks, Computer ; Algorithms ; Eyelids
Czasopismo naukowe
Tytuł:
Physical Noninvasive Attacks on Photoplethysmogram by Computer Controlled Blood Pressure Cuff.
Autorzy:
Yoshida K; Graduate School of Information Science and Engineering, Ritsumeikan University, 1-1-1 Nojihigashi, Shiga, Kusatsu 525-8577, Japan.
Sawano R; Graduate School of Information Science and Engineering, Ritsumeikan University, 1-1-1 Nojihigashi, Shiga, Kusatsu 525-8577, Japan.
Okamoto M; Graduate School of Information Science and Engineering, Ritsumeikan University, 1-1-1 Nojihigashi, Shiga, Kusatsu 525-8577, Japan.
Murao K; Graduate School of Information Science and Engineering, Ritsumeikan University, 1-1-1 Nojihigashi, Shiga, Kusatsu 525-8577, Japan.
Tsuchida S; Center for Interdisciplinary AI and Data Science, Ochanomizu University, 2-1-1 Otsuka, Bunkyo-ku, Tokyo 112-8610, Japan.
Terada T; Graduate School of Engineering, Kobe University, 1-1 Rokkodai-cho, Nada-ku, Hyogo, Kobe 657-8501, Japan.
Pokaż więcej
Źródło:
Sensors (Basel, Switzerland) [Sensors (Basel)] 2023 Dec 11; Vol. 23 (24). Date of Electronic Publication: 2023 Dec 11.
Typ publikacji:
Journal Article
MeSH Terms:
Photoplethysmography*/methods
Blood Pressure Determination*/methods
Humans ; Blood Pressure/physiology ; Heart Rate/physiology ; Computers
Czasopismo naukowe
Tytuł:
TRCCBP: Transformer Network for Radar-Based Contactless Continuous Blood Pressure Monitoring.
Autorzy:
Jiang X; School of Artificial Intelligence, Beijing University of Posts and Telecommunications, Beijing 100876, China.
Zhang J; Logistic Support Center, Chinese PLA General Hospital, Beijing 100853, China.
Mu W; School of Artificial Intelligence, Beijing University of Posts and Telecommunications, Beijing 100876, China.
Wang K; Logistic Support Center, Chinese PLA General Hospital, Beijing 100853, China.
Li L; School of Artificial Intelligence, Beijing University of Posts and Telecommunications, Beijing 100876, China.
Zhang L; School of Artificial Intelligence, Beijing University of Posts and Telecommunications, Beijing 100876, China.
Pokaż więcej
Źródło:
Sensors (Basel, Switzerland) [Sensors (Basel)] 2023 Dec 07; Vol. 23 (24). Date of Electronic Publication: 2023 Dec 07.
Typ publikacji:
Journal Article
MeSH Terms:
Radar*
Photoplethysmography*/methods
Blood Pressure/physiology ; Blood Pressure Determination/methods ; Monitoring, Physiologic/methods ; Pulse Wave Analysis/methods
Czasopismo naukowe
Tytuł:
The impact of healthy pregnancy on features of heart rate variability and pulse wave morphology derived from wrist-worn photoplethysmography.
Autorzy:
Bester M; Department of Electrical Engineering, Eindhoven University of Technology, 5612 AZ, Eindhoven, The Netherlands. .; Patient Care and Monitoring, Philips Research, 5656 AE, Eindhoven, The Netherlands. .
Almario Escorcia MJ; Patient Care and Monitoring, Philips Research, 5656 AE, Eindhoven, The Netherlands.; Department of Electronics, Information and Bioengineering, Politecnico di Milano, 20133, Milan, MI, Italy.
Fonseca P; Department of Electrical Engineering, Eindhoven University of Technology, 5612 AZ, Eindhoven, The Netherlands.; Patient Care and Monitoring, Philips Research, 5656 AE, Eindhoven, The Netherlands.
Mollura M; Department of Electronics, Information and Bioengineering, Politecnico di Milano, 20133, Milan, MI, Italy.
van Gilst MM; Department of Electrical Engineering, Eindhoven University of Technology, 5612 AZ, Eindhoven, The Netherlands.; Sleep Medicine Center Kempenhaeghe, 5591 VE, Heeze, The Netherlands.
Barbieri R; Department of Electronics, Information and Bioengineering, Politecnico di Milano, 20133, Milan, MI, Italy.
Mischi M; Department of Electrical Engineering, Eindhoven University of Technology, 5612 AZ, Eindhoven, The Netherlands.
van Laar JOEH; Department of Electrical Engineering, Eindhoven University of Technology, 5612 AZ, Eindhoven, The Netherlands.; Department of Obstetrics and Gynecology, Máxima Medical Centrum, De Run 4600, 5504 DB, Veldhoven, The Netherlands.
Vullings R; Department of Electrical Engineering, Eindhoven University of Technology, 5612 AZ, Eindhoven, The Netherlands.
Joshi R; Patient Care and Monitoring, Philips Research, 5656 AE, Eindhoven, The Netherlands.
Pokaż więcej
Źródło:
Scientific reports [Sci Rep] 2023 Nov 30; Vol. 13 (1), pp. 21100. Date of Electronic Publication: 2023 Nov 30.
Typ publikacji:
Journal Article
MeSH Terms:
Wrist*
Photoplethysmography*
Humans ; Female ; Pregnancy ; Heart Rate/physiology ; Wrist Joint ; Health Status ; Electrocardiography
Czasopismo naukowe
Tytuł:
A Comparative Analysis of Various Machine Learning Algorithms to Improve the Accuracy of HbA1c Estimation Using Wrist PPG Data.
Autorzy:
Satter S; Department of Electronics Engineering, Kookmin University, Seoul 02707, Republic of Korea.
Kwon TH; Department of Electronics Engineering, Kookmin University, Seoul 02707, Republic of Korea.
Kim KD; Department of Electronics Engineering, Kookmin University, Seoul 02707, Republic of Korea.
Pokaż więcej
Źródło:
Sensors (Basel, Switzerland) [Sensors (Basel)] 2023 Aug 17; Vol. 23 (16). Date of Electronic Publication: 2023 Aug 17.
Typ publikacji:
Comparative Study; Journal Article
MeSH Terms:
Machine Learning*
Photoplethysmography*/instrumentation
Photoplethysmography*/methods
Humans ; Wrist
Czasopismo naukowe
Tytuł:
Anomaly Detection in Multi-Wavelength Photoplethysmography Using Lightweight Machine Learning Algorithms.
Autorzy:
Baciu VE; Department of Electronics and Informatics (ETRO), Vrije Universiteit Brussel (VUB), 1050 Brussels, Belgium.
Lambert Cause J; Department of Electronics and Informatics (ETRO), Vrije Universiteit Brussel (VUB), 1050 Brussels, Belgium.; Department of Biomedical Engineering, Universidad de Oriente, Santiago de Cuba 90500, Cuba.
Solé Morillo Á; Department of Electronics and Informatics (ETRO), Vrije Universiteit Brussel (VUB), 1050 Brussels, Belgium.
García-Naranjo JC; Centre of Medical Biophysics, Universidad de Oriente, Santiago de Cuba 90500, Cuba.
Stiens J; Department of Electronics and Informatics (ETRO), Vrije Universiteit Brussel (VUB), 1050 Brussels, Belgium.
da Silva B; Department of Electronics and Informatics (ETRO), Vrije Universiteit Brussel (VUB), 1050 Brussels, Belgium.
Pokaż więcej
Źródło:
Sensors (Basel, Switzerland) [Sensors (Basel)] 2023 Aug 04; Vol. 23 (15). Date of Electronic Publication: 2023 Aug 04.
Typ publikacji:
Journal Article
MeSH Terms:
Photoplethysmography*
Algorithms*
Reproducibility of Results ; Heart Rate/physiology ; Machine Learning ; Artifacts ; Signal Processing, Computer-Assisted
Czasopismo naukowe
Tytuł:
On the cardiorespiratory coordination assessed by the photoplethysmography imaging technique.
Autorzy:
Borik S; Department of Electromagnetic and Biomedical Engineering, Faculty of Electrical Engineering and Information Technology, University of Zilina, Zilina, Slovakia. .
Keller M; Department of Psychiatry, Psychotherapy and Psychosomatics, Medical School, RWTH Aachen University, Aachen, Germany.
Perlitz V; Simplana GmbH, Aachen, Germany.
Lyra S; Medical Information Technology (MedIT), Helmholtz-Institute for Biomedical Engineering, RWTH Aachen University, Aachen, Germany.
Pelz H; Deutsche Gesellschaft für Osteopathische Medizin (DGOM), Mannheim, Germany.
Müller G; Simplana GmbH, Aachen, Germany.
Leonhardt S; Medical Information Technology (MedIT), Helmholtz-Institute for Biomedical Engineering, RWTH Aachen University, Aachen, Germany.
Blazek V; Medical Information Technology (MedIT), Helmholtz-Institute for Biomedical Engineering, RWTH Aachen University, Aachen, Germany.; The Czech Institute of Informatics, Robotics and Cybernetics (CIIRC), Czech Technical University in Prague, Prague, Czech Republic.
Pokaż więcej
Źródło:
Scientific reports [Sci Rep] 2023 Sep 05; Vol. 13 (1), pp. 14645. Date of Electronic Publication: 2023 Sep 05.
Typ publikacji:
Journal Article; Research Support, Non-U.S. Gov't
MeSH Terms:
Photoplethysmography*
Autonomic Nervous System*
Humans ; Clinical Relevance ; Heart ; Pain
Czasopismo naukowe
Tytuł:
Novel Multi-Parametric Sensor System for Comprehensive Multi-Wavelength Photoplethysmography Characterization.
Autorzy:
Lambert Cause J; Department of Electronics and Informatics (ETRO), Vrije Universiteit Brussel (VUB), 1050 Brussels, Belgium.; Department of Biomedical Engineering, Universidad de Oriente, Santiago de Cuba 90500, Cuba.
Solé Morillo Á; Department of Electronics and Informatics (ETRO), Vrije Universiteit Brussel (VUB), 1050 Brussels, Belgium.
da Silva B; Department of Electronics and Informatics (ETRO), Vrije Universiteit Brussel (VUB), 1050 Brussels, Belgium.
García-Naranjo JC; Centre of Medical Biophysics, Universidad de Oriente, Santiago de Cuba 90500, Cuba.
Stiens J; Department of Electronics and Informatics (ETRO), Vrije Universiteit Brussel (VUB), 1050 Brussels, Belgium.
Pokaż więcej
Źródło:
Sensors (Basel, Switzerland) [Sensors (Basel)] 2023 Jul 24; Vol. 23 (14). Date of Electronic Publication: 2023 Jul 24.
Typ publikacji:
Journal Article
MeSH Terms:
Photoplethysmography*/methods
Signal Processing, Computer-Assisted*
Humans ; Reproducibility of Results ; Volunteers ; Fingers ; Heart Rate
Czasopismo naukowe
Tytuł:
The Principles of Hearable Photoplethysmography Analysis and Applications in Physiological Monitoring-A Review.
Autorzy:
Azudin K; Department of Electrical, Electronic & Systems Engineering, Faculty of Engineering and Built Environment, Universiti Kebangsaan Malaysia, Bangi 43600, Selangor, Malaysia.
Gan KB; Department of Electrical, Electronic & Systems Engineering, Faculty of Engineering and Built Environment, Universiti Kebangsaan Malaysia, Bangi 43600, Selangor, Malaysia.
Jaafar R; Department of Electrical, Electronic & Systems Engineering, Faculty of Engineering and Built Environment, Universiti Kebangsaan Malaysia, Bangi 43600, Selangor, Malaysia.
Ja'afar MH; Department of Community Health, Faculty of Medicine, UKM Medical Centre, Universiti Kebangsaan Malaysia, Cheras 56000, Kuala Lumpur, Malaysia.
Pokaż więcej
Źródło:
Sensors (Basel, Switzerland) [Sensors (Basel)] 2023 Jul 18; Vol. 23 (14). Date of Electronic Publication: 2023 Jul 18.
Typ publikacji:
Journal Article; Review
MeSH Terms:
Photoplethysmography*
Arteries*
Monitoring, Physiologic ; Blood Pressure ; Respiratory Rate ; Heart Rate ; Signal Processing, Computer-Assisted
Czasopismo naukowe
Tytuł:
Precision Heart Rate Estimation Using a PPG Sensor Patch Equipped with New Algorithms of Pre-Quality Checking and Hankel Decomposition.
Autorzy:
Thakur S; Department of Electronics and Electrical Engineering, National Yang Ming Chiao Tung University, Hsinchu 300, Taiwan.
Chao PC; Department of Electronics and Electrical Engineering, National Yang Ming Chiao Tung University, Hsinchu 300, Taiwan.
Tsai CH; Department of Electronics and Electrical Engineering, National Yang Ming Chiao Tung University, Hsinchu 300, Taiwan.
Pokaż więcej
Źródło:
Sensors (Basel, Switzerland) [Sensors (Basel)] 2023 Jul 05; Vol. 23 (13). Date of Electronic Publication: 2023 Jul 05.
Typ publikacji:
Journal Article
MeSH Terms:
Photoplethysmography*/methods
Exercise*/physiology
Humans ; Heart Rate/physiology ; Signal Processing, Computer-Assisted ; Algorithms ; Artifacts
Czasopismo naukowe
Tytuł:
Pulse Oximetry Based on Quadrature Multiplexing of the Amplitude Modulated Photoplethysmographic Signals.
Autorzy:
Koseeyaporn J; School of Engineering, King Mongkut's Institute of Technology Ladkrabang, Bangkok 10520, Thailand.
Wardkein P; School of Engineering, King Mongkut's Institute of Technology Ladkrabang, Bangkok 10520, Thailand.
Sinchai A; College of Advanced Manufacturing Innovation, King Mongkut's Institute of Technology Ladkrabang, Bangkok 10520, Thailand.
Kainan P; School of Engineering, King Mongkut's Institute of Technology Ladkrabang, Bangkok 10520, Thailand.
Tuwanut P; School of Information Technology, King Mongkut's Institute of Technology Ladkrabang, Bangkok 10520, Thailand.
Pokaż więcej
Źródło:
Sensors (Basel, Switzerland) [Sensors (Basel)] 2023 Jul 02; Vol. 23 (13). Date of Electronic Publication: 2023 Jul 02.
Typ publikacji:
Journal Article
MeSH Terms:
Photoplethysmography*/methods
Oximetry*/methods
Oxygen ; Movement ; Hand
Czasopismo naukowe

Ta witryna wykorzystuje pliki cookies do przechowywania informacji na Twoim komputerze. Pliki cookies stosujemy w celu świadczenia usług na najwyższym poziomie, w tym w sposób dostosowany do indywidualnych potrzeb. Korzystanie z witryny bez zmiany ustawień dotyczących cookies oznacza, że będą one zamieszczane w Twoim komputerze. W każdym momencie możesz dokonać zmiany ustawień dotyczących cookies