Informacja

Drogi użytkowniku, aplikacja do prawidłowego działania wymaga obsługi JavaScript. Proszę włącz obsługę JavaScript w Twojej przeglądarce.

Wyszukujesz frazę ""Schoepf, U Joseph"" wg kryterium: Autor


Wyświetlanie 1-4 z 4
Tytuł:
Automated detection of lung nodules and coronary artery calcium using artificial intelligence on low-dose CT scans for lung cancer screening: accuracy and prognostic value.
Autorzy:
Chamberlin J; Department of Radiology, Medical University of South Carolina, Charleston, SC, 29403, USA.
Kocher MR; Department of Radiology, Medical University of South Carolina, Charleston, SC, 29403, USA.
Waltz J; Department of Radiology, Medical University of South Carolina, Charleston, SC, 29403, USA.
Snoddy M; Department of Radiology, Medical University of South Carolina, Charleston, SC, 29403, USA.
Stringer NFC; Department of Radiology, Medical University of South Carolina, Charleston, SC, 29403, USA.
Stephenson J; Department of Radiology, Medical University of South Carolina, Charleston, SC, 29403, USA.
Sahbaee P; Siemens Healthineers, Princeton, NJ, USA.
Sharma P; Siemens Healthineers, Princeton, NJ, USA.
Rapaka S; Siemens Healthineers, Princeton, NJ, USA.
Schoepf UJ; Department of Radiology, Medical University of South Carolina, Charleston, SC, 29403, USA.
Abadia AF; Department of Radiology, Medical University of South Carolina, Charleston, SC, 29403, USA.
Sperl J; Siemens Healthineers, Princeton, NJ, USA.
Hoelzer P; Siemens Healthineers, Princeton, NJ, USA.
Mercer M; Department of Radiology, Medical University of South Carolina, Charleston, SC, 29403, USA.
Somayaji N; Department of Radiology, Medical University of South Carolina, Charleston, SC, 29403, USA.
Aquino G; Department of Radiology, Medical University of South Carolina, Charleston, SC, 29403, USA.
Burt JR; Department of Radiology, Medical University of South Carolina, Charleston, SC, 29403, USA. .; MUSC-ART, Cardiothoracic Imaging, 25 Courtenay Drive, MSC 226, 2nd Floor, Rm 2256, Charleston, SC, 29425, USA. .
Pokaż więcej
Źródło:
BMC medicine [BMC Med] 2021 Mar 04; Vol. 19 (1), pp. 55. Date of Electronic Publication: 2021 Mar 04.
Typ publikacji:
Journal Article
MeSH Terms:
Artificial Intelligence/*standards
Calcium/*metabolism
Coronary Vessels/*physiopathology
Early Detection of Cancer/*methods
Lung Neoplasms/*diagnosis
Tomography, X-Ray Computed/*methods
Cohort Studies ; Female ; Humans ; Lung Neoplasms/pathology ; Male ; Prognosis ; Retrospective Studies
Czasopismo naukowe
Tytuł:
Robot-assisted percutaneous placement of K-wires during minimally invasive interventions of the spine.
Autorzy:
Croissant Y; Department of Orthopedic and Trauma Surgery, St Josefs-Hospital Wiesbaden, Wiesbaden, Germany.; Department of Diagnostic and Interventional Radiology, University Hospital Frankfurt, Frankfurt am Main, Germany.
Zangos S; Department of Diagnostic and Interventional Radiology, University Hospital Frankfurt, Frankfurt am Main, Germany.
Albrecht MH; Department of Diagnostic and Interventional Radiology, University Hospital Frankfurt, Frankfurt am Main, Germany.
Eichler K; Department of Diagnostic and Interventional Radiology, University Hospital Frankfurt, Frankfurt am Main, Germany.
Schomerus C; Institute of Anatomy, Goethe University Frankfurt, Frankfurt am Main, Germany.
Spandorfer A; Department of Radiology and Radiological Science, Medical University of South Carolina, Charleston SC, United States.
Schoepf UJ; Department of Radiology and Radiological Science, Medical University of South Carolina, Charleston SC, United States.
Vogl TJ; Department of Diagnostic and Interventional Radiology, University Hospital Frankfurt, Frankfurt am Main, Germany.
Czerny C; Department of Trauma Surgery, University Hospital Frankfurt, Frankfurt am Main, Germany.
Pokaż więcej
Źródło:
Minimally invasive therapy & allied technologies : MITAT : official journal of the Society for Minimally Invasive Therapy [Minim Invasive Ther Allied Technol] 2019 Dec; Vol. 28 (6), pp. 373-380. Date of Electronic Publication: 2018 Nov 15.
Typ publikacji:
Journal Article
MeSH Terms:
Robotics*
Tomography, X-Ray Computed*
Lumbar Vertebrae/*surgery
Bone Wires ; Humans ; Surgery, Computer-Assisted/methods
Czasopismo naukowe
Tytuł:
Prospectively ECG-Triggered Sequential Dual-Source Coronary CT Angiography in Patients with Atrial Fibrillation: Influence of Heart Rate on Image Quality and Evaluation of Diagnostic Accuracy.
Autorzy:
Yang L; Department of Radiology, Beijing Anzhen Hospital, Capital Medical University, Beijing, China.
Xu L; Department of Radiology, Beijing Anzhen Hospital, Capital Medical University, Beijing, China.
Schoepf UJ; Department of Radiology and Radiological Science, Medical University of South Carolina, Charleston, SC, United States of America.
Wichmann JL; Department of Radiology and Radiological Science, Medical University of South Carolina, Charleston, SC, United States of America.
Fox MA; Department of Radiology and Radiological Science, Medical University of South Carolina, Charleston, SC, United States of America.
Yan J; Siemens Healthcare China, 278 Zhouzhu Road, Shanghai, China.
Fan Z; Department of Radiology, Beijing Anzhen Hospital, Capital Medical University, Beijing, China.
Zhang Z; Department of Radiology, Beijing Anzhen Hospital, Capital Medical University, Beijing, China.
Pokaż więcej
Źródło:
PloS one [PLoS One] 2015 Jul 29; Vol. 10 (7), pp. e0134194. Date of Electronic Publication: 2015 Jul 29 (Print Publication: 2015).
Typ publikacji:
Journal Article; Research Support, Non-U.S. Gov't
MeSH Terms:
Atrial Fibrillation/*diagnosis
Atrial Fibrillation/*diagnostic imaging
Coronary Angiography/*methods
Tomography, X-Ray Computed/*methods
Adult ; Aged ; Aged, 80 and over ; Analysis of Variance ; Atrial Fibrillation/physiopathology ; Cardiac-Gated Imaging Techniques/methods ; Electrocardiography ; Female ; Heart Rate ; Humans ; Male ; Middle Aged ; Prospective Studies ; Radiographic Image Interpretation, Computer-Assisted
Czasopismo naukowe
    Wyświetlanie 1-4 z 4

    Ta witryna wykorzystuje pliki cookies do przechowywania informacji na Twoim komputerze. Pliki cookies stosujemy w celu świadczenia usług na najwyższym poziomie, w tym w sposób dostosowany do indywidualnych potrzeb. Korzystanie z witryny bez zmiany ustawień dotyczących cookies oznacza, że będą one zamieszczane w Twoim komputerze. W każdym momencie możesz dokonać zmiany ustawień dotyczących cookies